MF28
This equipment is aimed to GENERATE PULSE of CURRENT on pyrotechnical elements where the SAFETY of USERS is directly at stake.
For instrumented and performance tests
Programmable generator that controls current of non-fire, time / energy of activation...
High flexible units: Other specifications / options on demand
Major issue - Ensuring safety
Our exploders integrate a safety pyrotechnical ohmmeter allowing to limit and control CURRENT, even in case of failure (continuity test).
All versions are equipped with a powerful SQUARE PULSE GENERATOR of current that controls the energy injected into the initiator.
Very short rising time (< 10 μ s)
No overshoot
Residual discharges are removed in order to prevent inopportune activation (Thanks to short
circuit of shot firing cables)
Various safety modules ensure user safety: key, push rod protected, external safety entrance
for door / gate contact switches
The calibration of pyrotechnical firing units shall be yearly carried out, as well as a comprehensive checking of the safety functions of the equipment.
Technical features
* Programmable current (1% accuracy)
* Programmable timing
* Isolated floating shot firing cable
* Embedded safety ohmmeter
* 3 synchronization outputs (zero time, crenel current, current image)
* Optional remotre control of the cycle SAFE AUTHORIZATION OF FIRE